Black Widow Security BW FM 250 Manual de instalación Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
15
If the power trunk re-lease
requires a positive pulse to
operate, use this circuit.
2nd CHANNEL
AUXILIARY
(GRAY WIRE)
12V
POSITIVE
OUT TO TRUNK 12V
FOR POSITIVE
PARKING LIGHTS
TRUNK RELEASE
CIRCUIT DIAGRAM:
VEHICLE
PARKING
LIGHT
WIRE
WHITE
87
8586
87a
30
FOR NEGATIVE
PARKING LIGHTS
(MOST
JAPANESE
VEHICLES)
87
8586
87a
30
TO VEHICLE
PARKING
LIGHT
CIRCUIT
WHITE
STATUS INDICATOR (LED) FUNCTIONS
Off= System off in Active Mode
Slow Flash= System Armed
Rapid Flash= Passive Pre Arm State
Rapid Flash (after disarm)= System was trig-
gered
On Solid= In Valet or Service Mode
On Solid= (After passive prearm or active
arm) 10 second final prearm state
On Solid= (when disarmed, and not in
Valet/Service Mode) -Input is open. See Test
Mode.
SILENT TEST MODE
When the system is disarmed the LED will
go solid every time an input is triggered. You
can check the shock sensor, doors, hood,
trunk, and the auxiliary sensor input as well.
SIREN CHIRP STATUS
1 chirp= system armed
2 chirps= system disarmed
3 chirps= System disarmed, but alarm was
triggered while away.
4 chirps= Alarm armed but there is a trigger
that remains open. (This occurs 25 seconds
after system was armed)
5 rapid chirps= Alarm armed, shock sensor
warn away output was triggered.
DIP SWITCH PROGRAMMABLE FEATURES
Switch Description ON OFF
#1 Lock/Unlock Pulse Time .75 seconds 3 seconds
#2 Ignition Triggered Door Locks Feature On Feature Off
#3 Passive Door Locks Feature On Feature OFF
#4 Passive or Active Arming Passive Arming, Active arming
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16

Comentarios a estos manuales

Sin comentarios